0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TRV 1-1523M

TRV 1-1523M

  • 厂商:

    TRACOPOWER

  • 封装:

    SIP5 模块

  • 描述:

    隔离模块 直流转换器 2 输出 15V -15V 34mA,34mA 12V - 18V 输入

  • 数据手册
  • 价格&库存
TRV 1-1523M 数据手册
DC/DC Medical Converter • • • • I/O isolation 5000 VAC (reinforced) • Operating temperature range -40 to +95 °C without derating • Certification according to IEC/EN/ES 60601-1 3rd edition for 2xMOPP and IEC/EN/UL 62368-1 • • • • Low leakage current < 2 μA TRV 1M Series, 1 Watt Short circuit protection Semi-regulated outputs ES 60601-1 IEC 60601-1 UL 62368-1 IEC 62368-1 Input voltage ranges (±10%): 5, 12, 15, 24 VDC Efficiency up to 85% Operation up to 5000 m altitude 5-year product warranty The TRV 1M is a series of 1 Watt DC/DC converters in a compact SIP-9 package with reinforced isolation of 5000 VAC for medical and industrial applications. The series offers models with different input voltages (±10%) between 5 and 24 VDC. With a continuous short circuit protection and a low leakage current of less than 2 µA, this converter series is especially suited to protect any connected interfaces or applied parts to patients. Featuring semi-regulated outputs this series provides a good level of regulation without affecting the cost efficiency. It is an ideal solution for applications where a completely unregulated DC/DC converter would not meet you regulation requirements and therefore opens up the overall application range of this series. Together with an operating temperature range from -40 to +95°C without derating and certifications according to IEC/EN/ES 60601-1 3rd ed. for 2xMOPP and IEC/EN/UL 62368-1 this series is suitable for many different applications where a medical isolation system and short circuit protection is needed. Models Order Code Input Voltage Range TRV 1-0510M TRV 1-0511M TRV 1-0512M TRV 1-0513M TRV 1-0521M TRV 1-0522M TRV 1-0523M TRV 1-1210M TRV 1-1211M TRV 1-1212M TRV 1-1213M TRV 1-1221M TRV 1-1222M TRV 1-1223M TRV 1-1510M TRV 1-1511M TRV 1-1512M TRV 1-1513M TRV 1-1521M TRV 1-1522M TRV 1-1523M TRV 1-2410M TRV 1-2411M TRV 1-2412M TRV 1-2413M TRV 1-2421M TRV 1-2422M TRV 1-2423M Note 4.5 - 5.5 VDC (5 VDC nom.) 9.6 - 14.4 VDC (12 VDC nom.) 12 - 18 VDC (15 VDC nom.) 19.2 - 28.8 VDC (24 VDC nom.) Output 1 Output 2 Vnom Imax 3.3 VDC 5 VDC 12 VDC 15 VDC +5 VDC +12 VDC +15 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC +5 VDC +12 VDC +15 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC +5 VDC +12 VDC +15 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC +5 VDC +12 VDC +15 VDC 303 mA 200 mA 83 mA 67 mA 100 mA 42 mA 34 mA 303 mA 200 mA 83 mA 67 mA 100 mA 42 mA 34 mA 303 mA 200 mA 83 mA 67 mA 100 mA 42 mA 34 mA 303 mA 200 mA 83 mA 67 mA 100 mA 42 mA 34 mA Vnom Efficiency Imax –5 VDC –12 VDC –15 VDC 100 mA 42 mA 34 mA –5 VDC –12 VDC –15 VDC 100 mA 42 mA 34 mA –5 VDC –12 VDC –15 VDC 100 mA 42 mA 34 mA –5 VDC –12 VDC –15 VDC 100 mA 42 mA 34 mA typ. 80 % 82 % 85 % 84 % 85 % 85 % 84 % 80 % 82 % 84 % 83 % 82 % 83 % 83 % 79 % 83 % 84 % 84 % 82 % 83 % 83 % 78 % 82 % 83 % 83 % 80 % 81 % 81 % - 5 Vin models: If the input is switched electromechanically, use an external 100 μF/10 V E/C. to reduce voltage transient. www.tracopower.com October 25, 2023 Page 1 / 4 TRV 1M Series, 1 Watt Input Specifications Input Current - At no load 5 Vin models: 12 Vin models: 15 Vin models: 24 Vin models: 5 Vin models: 12 Vin models: 15 Vin models: 24 Vin models: 5 Vin models: 12 Vin models: 15 Vin models: 24 Vin models: Surge Voltage Recommended Input Fuse 30 mA typ. 30 mA typ. 15 mA typ. 10 mA typ. 6 VDC max. (1 s max.) 25 VDC max. (1 s max.) 25 VDC max. (1 s max.) 40 VDC max. (1 s max.) 500 mA (slow blow) 315 mA (slow blow) 315 mA (slow blow) 160 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Output Specifications Voltage Set Accuracy Regulation - Input Variation (1% Vin step) Ripple and Noise - Load Variation - Cross Regulation (25% / 100% asym. load) - 20 MHz Bandwidth Capacitive Load - single output - dual output single output models: dual output models: See application note: dual output models: 3.3 Vout models: 5 Vout models: 12 Vout models: 15 Vout models: 5 / -5 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: Minimum Load Temperature Coefficient Short Circuit Protection ±3.5% max. (60% load: 3.3, 5, ±5 Vout models) ±3.5% max. (90% load: other models) 0.2% max. 0.2% max. www.tracopower.com/overview/trv1m 6% max. 75 mVp-p typ. 100 mVp-p max. 2'000 µF max. 820 µF max. 470 µF max. 470 µF max. 470 / 470 µF max. 220 / 220 µF max. 220 / 220 µF max. Not required ±0.03 %/K max. Continuous, Automatic recovery Safety Specifications Standards EN 62368-1 IEC 62368-1 UL 62368-1 EN 60601-1 IEC 60601-1 ANSI/AAMI ES 60601-1 2 x MOPP (Means Of Patient Protection) www.tracopower.com/overview/trv1m PD 2 - IT / Multimedia Equipment - Medical Equipment - Certification Documents Pollution Degree All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com October 25, 2023 Page 2 / 4 TRV 1M Series, 1 Watt EMC Specifications EMI Emissions - Conducted Emissions - Radiated Emissions External filter proposal: EMS Immunity - Electrostatic Discharge Air: Contact: - RF Electromagnetic Field - EFT (Burst) / Surge External filter proposal: - Conducted RF Disturbances - PF Magnetic Field Continuous: 1 s: EN 60601-1-2 edition 4 (Medical Devices) EN 55011 class A (with external filter) EN 55011 class B (with external filter) EN 55032 class A (with external filter) EN 55032 class B (with external filter) EN 55011 class A (with external filter) EN 55011 class B (with external filter) EN 55032 class A (with external filter) EN 55032 class B (with external filter) www.tracopower.com/overview/trv1m EN 60601-1-2 edition 4 (Medical Devices) EN 55024 (IT Equipment) EN 55035 (Multimedia) EN 61000-4-2, ±15 kV, perf. criteria A EN 61000-4-2, ±8 kV, perf. criteria A EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A www.tracopower.com/overview/trv1m EN 61000-4-6, 10 Vrms, perf. criteria A EN 61000-4-8, 100 A/m, perf. criteria A EN 61000-4-8, 1000 A/m, perf. criteria A General Specifications Relative Humidity Temperature Ranges Cooling System Altitude During Operation Switching Frequency Insulation System Working Voltage (rated) Isolation Test Voltage Creepage Clearance Isolation Resistance Isolation Capacitance - Operating Temperature - Case Temperature - Storage Temperature - Input to Output, 60 s - Input to Output - Input to Output - Input to Output, 500 VDC - Input to Output, 100 kHz, 1 V Leakage Current Reliability Washing Process - Touch Current - Calculated MTBF Environment - Vibration - Mechanical Shock - Thermal Shock Housing Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type 95% max. (non condensing) –40°C to +95°C (without derating) +105°C max. –55°C to +125°C Natural convection (20 LFM) 5'000 m max. 220 - 380 kHz (PWM) Reinforced Insulation 250 VAC 5'000 VAC 8 mm min. 8 mm min. 10'000 MΩ min. 15 pF typ. 20 pF max. 2 µA max. 19'360'000 h (MIL-HDBK-217F, ground benign) According to Cleaning Guideline www.tracopower.com/info/cleaning.pdf MIL-STD-810F MIL-STD-810F MIL-STD-810F Non-conductive Plastic (UL 94 V-0 rated) Silicone (UL 94 V-0 rated) Brass Nickel (1 - 2 µm) Tin (3 - 5 µm), matte Plastic Case PCB Mount THD (Through-Hole Device) SIP9 All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com October 25, 2023 Page 3 / 4 TRV 1M Series, 1 Watt Soldering Profile Lead-Free Wave Soldering 260°C / 6 s max. 4.8 g www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule).) 804cccb4-e301-4dbb-9ef4-8516768826e7 Weight Environmental Compliance - REACH Declaration - RoHS Declaration - SCIP Reference Number Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/trv1m Outline Dimensions 19.6 Pinout 2.0 1 +Vin (Vcc) +Vin (Vcc) 2 –Vin (GND) –Vin (GND) 7 –Vout –Vout 8 No pin Common 9 +Vout +Vout 2.0 (0.07) 9.9 1.8 (0.63) Bottom view (0.02x0.01) Dual (0.079) (0.079) 16.0 0.5x0.25 Single (0.39) 10.0 (0.394) Pin 9 4.1 2.0 (0.079) 8 (0.16) 7 2.3 2 (0.09) 1 (0.49) 12.5 (0.77) Dimensions in mm (inch) Tolerances: x.x ±0.5 (±0.02) x.xx ±0.25 (±0.01) Pin diameter ±0.1 (±0.004) © Copyright 2023 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. October 25, 2023 Page 4 / 4
TRV 1-1523M 价格&库存

很抱歉,暂时无法提供与“TRV 1-1523M”相匹配的价格&库存,您可以联系我们找货

免费人工找货